Health under control!

Ward patient monitor G3C

Ward patient monitor G3C Dynamic multiparameter monitoring of vital functions with automatic data analysis and adjustable visual and sound alarms.


Bright 10,4" display with adjustable data and simultaneous outputting up to 8 trends.
ECG with a function of automatic analisys of arrhythmia and ST segment.
Immunity to electrical interference, rapid recovery after defibrillation.
Base complectation of Ward patient monitor G3C: ECG, Respiratory rate (2 probes), Pulse, SpO2, non invasive ABP, temperature (2 probes), printer.
Option: invasive ABP(IBP), capnography (CO2), Wi-Fi, power from 12 volt, wall mounting, mobile stand.

Warranty term (month.): 18

Ward patient monitor G3C, complectation:

- Patient monitor - 1 pcs.
- Power cable -1 pcs.
- Extension cuff - 1 pcs.
- Cuff - 1 pcs.
- ECG cable - 1 pcs.
- Disposable ECG electrodes- 10 pcs.
- SPO2 probe - 1 pcs.
- Paper roll for printer - 1 pcs.
- Respiratory tube (disposable) - 1 pcs.
- Temperature probe (rectal and cutaneous) - 2 pcs.
- Manual - 1 pcs.
- Brand textile case - 1 pcs.
- Warranty - 1 pcs.

Technical characteristics on Ward patient monitor G3C:

ECG

Leads: Cable with 3 or 5 leads.
Lead selection: I,II,III/I,II,III aVR, aVL, aVF, V.
Gain selection: 1/4,1/2,1, 2, 4мВ or auto.
Sweep speed: 6.25,12.5, 25, and 50 мм/sec.
Pulse measurement range: 15-380 ВРМ (beats in a minute)
ECG calibration: ±1 мВ

Temperature

Two channel:central and peripheral.
Soltion: 0.1 °С (I,II,III selection of the impedance of the nasal cavity).
Temperature: Т1 ,Т2, ∆Т.

NIBP

Working mode:automatic oscillometric.
Measurement type: Adult, pediatric, neonatal.
Measured parameters: systolic, mean, diastolic pressure.
Measuring modes: manual, automatic and continuous.
Measurement unit: mm Hg/kPa (optional) Accuracy ±2 mmHg

SP02

Display Mode: curves and digital.
Measurement range: 0-100%.
Solution: 1%.
Pulse measurement range: 30-250 beats.min.
Pulse measurement range: ±1 beats.min.
Solution: beats.min.

Raspiration rate

Measurement method: thoracic impedance or nasal tube
Measurement range: adults : 0-120 breath/min.
Accuracy: ± 1 breath/min
Solution: 1 breath/min.

Cardiac output (option)

Method: thermodynamic.
Measurement range: СО: 0.1-20.0 L/min ТВ:23-43°С ТI:0-27°С. Solution: СО: 0.1 L/min ТI: 0.1°С ТВ: 0.1°С.
Accuracy: СО: ± 0.2 L/min or ± 5% ТВ: ± 0.2°С ТI: ± 0.2°С. Output parameter: calculation of hemodynamics.

Invasive arterial pressure  (option)

Measurement range: -6~40kPa (-50~300 mmHg).
Channel: 2 channel.
Pressure probe: sensitive: 5мВ/В/mmHg
Measurement unit: mmHg/kPa.

Capnography (ЕтСО2) (main stream and side stream)

Method: main stream and side stream.
Measurement range: 0%-10.0%.
Accuracy: ± 2 mmHg